Gather all required measurement equipment before leaving the office
ContextYou'll need a calibrated high-impedance digital voltmeter (input impedance ≥10 MΩ — lower impedance introduces an IR error that inflates apparent protection), a copper/copper sulfate reference electrode (CSE) in good working condition, and a full set of clip leads. A sluggish or depleted CSE can skew readings by 50–100 mV — more than enough to falsely indicate criterion compliance. Pack the previous month's log sheet as a field reference for comparison; trending data in hand during the survey is worth far more than reviewing it back at the office.